Human CD127/IL7R/IL7RA/CDw127/IL7Ralpha Lentivirus, Full-length Gene in Lentivector, Pre-packaged Lentiviral Particles
CD127, also known as IL7RA/IL7R (Interleukin-7 receptor subunit alpha), is a single pass, type I transmembrane glycoprotein of the type I cytokine receptor family, type 4 subfamily. CD127 consists of a extracellular region with 1 fibronectin type III (FN3) domains and a juxtamembrane WSXWS motif, a transmembrane domain, and a cytoplasmic tail with the box 1 motif. The WSXWS motif is necessary for proper protein folding and efficient intracellular transport and cell-surface receptor binding, while the box 1 motif is required for JAK interaction/activation. CD127 is a component of the receptor complex for interleukin-7 and thymic stromal lymphopoietin (TSLP). The IL7 receptor complex is a heterodimer of CD127/IL7R and the common subunit CD132/IL2RG shared by the receptors for interleukins 2, 4, 7, 9, and 15.. The TSLP receptor complex is a heterodimer of TSLPR/CRLF2 and CD127/IL7R. CD127 has been shown to play a critical role in V(D)J recombination during lymphocyte development. Defects in the CD127 gene may be associated with severe combined immunodeficiency (SCID) and multiple sclerosis 3 (MS3).
Gene Symbol: IL7R; ILRA; CD127; IL7RA; CDW127; IL-7R-alpha
NCBI Gene ID: 3575
Uniprot Entry: P16871
Construct Details: Full length human CD127/IL7R gene is subcloned into the Lentiviral expression vector pLTC with an upstream CMV promoter and with or without a selection marker, which can be used for both transient and stable expression in mammalian cells. It can be co-transfected with the LentiPAK DNA mix (SKU# LP-001) into HEK293 cells to produce high titer lentiviral particles. Multiple choices of a stable antibiotic selection marker are available.
Vector Type: pLTC or pLTC-IRES-Marker (lentiviral expression vector containing a heterologous CMV promoter, see the vector map above)
Gene Insert Sequence:
ATGACAATTCTAGGTACAACTTTTGGCATGGTTTTTTCTTTACTTCAAGTCGTTTCTGGAGAAAGTGGCT
ATGCTCAAAATGGAGACTTGGAAGATGCAGAACTGGATGACTACTCATTCTCATGCTATAGCCAGTTGGA
AGTGAATGGATCGCAGCACTCACTGACCTGTGCTTTTGAGGACCCAGATGTCAACATCACCAATCTGGAA
TTTGAAATATGTGGGGCCCTCGTGGAGGTAAAGTGCCTGAATTTCAGGAAACTACAAGAGATATATTTCA
TCGAGACAAAGAAATTCTTACTGATTGGAAAGAGCAATATATGTGTGAAGGTTGGAGAAAAGAGTCTAAC
CTGCAAAAAAATAGACCTAACCACTATAGTTAAACCTGAGGCTCCTTTTGACCTGAGTGTCGTCTATCGG
GAAGGAGCCAATGACTTTGTGGTGACATTTAATACATCACACTTGCAAAAGAAGTATGTAAAAGTTTTAA
TGCACGATGTAGCTTACCGCCAGGAAAAGGATGAAAACAAATGGACGCATGTGAATTTATCCAGCACAAA
GCTGACACTCCTGCAGAGAAAGCTCCAACCGGCAGCAATGTATGAGATTAAAGTTCGATCCATCCCTGAT
CACTATTTTAAAGGCTTCTGGAGTGAATGGAGTCCAAGTTATTACTTCAGAACTCCAGAGATCAATAATA
GCTCAGGGGAGATGGATCCTATCTTACTAACCATCAGCATTTTGAGTTTTTTCTCTGTCGCTCTGTTGGT
CATCTTGGCCTGTGTGTTATGGAAAAAAAGGATTAAGCCTATCGTATGGCCCAGTCTCCCCGATCATAAG
AAGACTCTGGAACATCTTTGTAAGAAACCAAGAAAAAATTTAAATGTGAGTTTCAATCCTGAAAGTTTCC
TGGACTGCCAGATTCATAGGGTGGATGACATTCAAGCTAGAGATGAAGTGGAAGGTTTTCTGCAAGATAC
GTTTCCTCAGCAACTAGAAGAATCTGAGAAGCAGAGGCTTGGAGGGGATGTGCAGAGCCCCAACTGCCCA
TCTGAGGATGTAGTCATCACTCCAGAAAGCTTTGGAAGAGATTCATCCCTCACATGCCTGGCTGGGAATG
TCAGTGCATGTGACGCCCCTATTCTCTCCTCTTCCAGGTCCCTAGACTGCAGGGAGAGTGGCAAGAATGG
GCCTCATGTGTACCAGGACCTCCTGCTTAGCCTTGGGACTACAAACAGCACGCTGCCCCCTCCATTTTCT
CTCCAATCTGGAATCCTGACATTGAACCCAGTTGCTCAGGGTCAGCCCATTCTTACTTCCCTGGGATCAA
ATCAAGAAGAAGCATATGTCACCATGTCCAGCTTCTACCAAAACCAGTGA
Formulation: Lentivector encoded and pre-packaged viral particles (typical titer 106 - 107 IFU/ml) in the conditional medium (serum-free) from HEK293 cells that have been transfected with the lentivector gene clone and the LentiPAK DNA mix
FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE IN HUMAN.
Important Safety Information: With the safety features in place, our lentiviral vectors and viral particles can be employed in standard Biosafety Level 2 tissue culture facilities and should be treated with the same level of caution as any other potentially infectious agent. Any investigator who purchases our lentiviral/retroviral products & services is responsible for following Biosafety Level 2 requirements on the handling of viral particles. For more information on Biosafety Level 2 agents and practices, please refer to NIH’s “Biosafety Considerations for Research with Lentiviral Vectors”.
Restriction: This product is not transferable or re-sellable. Customer obtain no right to transfer, assign, or sublicense its use rights, or to transfer, resell, package, or otherwise distribute the product, or to use the product for the benefit of any third party or for any commercial purpose. Customer may only use the product in compliance with applicable local, state and federal laws, regulations and rules. Customer may not directly or indirectly use the product or allow the transfer, transmission, export or re-export of all or any part of the product in violation of any export control law or regulation of the united states or any other relevant jurisdiction. Your use of this product constitutes acceptance of the terms of this limited use agreement. Please refer to our “terms & conditions” for details. If you are not willing to accept the limitation of this agreement, G&P Biosciences will accept return of the product for a full/partial refund.
Pre-packaged lentiviral particles are most advanced gene delivery tools. Each particles contain a fully sequence verified target gene and are psudotyped with the VSV-G glycoprotein, ready for transduction into into a wide range of cell types including hard-to-transfect primary cells and non-dividing cells. They are supplied in 1-mL aliquot(s) of the serum-/antibiotic-free solution suitable for both in vitro and in vivo delivery. They are produced in HEK293 packaging cells with a typical titer of ≥107 IFU/ml using our optimized LentPAKTM packaging system. The lentiviral particles can be used to transduce subconfluent target cells. Depending on your purpose, you may choose a specific multiplicity of infection (MOI) or test a range of MOIs to determine which gives you the desired results. Transduction can be enhanced by the addition of polybrene, also known as hexadimethrine bromide (typically at 8-10 μg/ml).
Quick Protocol for Transduction
Day 1. Seeding Target Cells
For an example, plate target cells in a 10 cm plate at a density of 1 - 5x 105 cells/ml that will produce approximately 60% confluency in 24 hours.
Note: other size plates can also be used depending on the nature of your experiment. Adjust the reagent amount according to Table 1
Table 1. Seeding Density of Target Cells (1 day prior to transduction)
Vessel Type |
Seeding Density |
Volume of Media |
10-cm dish |
1 – 5 x 106 |
10 mL |
6-well plate |
0.3 – 1 x 106 |
2 mL/well |
12-well plate |
0.15 – 0.5 x 106 |
1 mL/well |
24-well plate |
0.6 – 2 x 105 |
0.5 mL/well |
96-well plate |
1 – 4 x 104 |
0.1 mL/well |
Day 2. Transduction
Remove the growth media from the dish/plate prepared the day before. Replace with 1/2 volume of culture medium containing desired amount of lentiviral particles (at 2 to 20 MOI). For example, add 4.5 mL of growth medium and 0.5 mL of Lentiviral particles, or simply add 5 mL of Lentiviral particles (for a low titer viral preparation or a high MOI transduction). Add polybrene directly to the media on the target cells at 8 μg/ml. Mix by gentle swirling.
Incubate at 37°C with 5% CO2 for 4 - 24 hours, then replace the transduction medium with right amount of growth medium according to table 1 (for example 10 mL for 10-cm dish). Culture the cells for 48 – 72 hours, and transduced cells are ready for downstream analyses.
Note: Adjust volumes accordingly for transduction of other plate types. For example, add 1 ml of growth medium and lentiviral particle mixture for 6-well plate, 0.5 ml for 12-well and 0.25 mL for 24-well except for 96 well, in which 100 μl should be used. The change of transduction medium is often unnecessary with our pre-packaged lentiviral particles. Simply culture cells for 3-4 days before analysis.
The virus-containing media can be changed in as short as 4 hours after transduction if toxicity of the lentiviral transduction is a concern. Normally reverse transcription and genome integration of the lentivector takes place within 24-36 hours. With our ready-to-use, prepackaged lentiviral particles, the change of media is often unnecessary. The transduction process can be ongoing for 2 - 6 days without significant impact on cell growth/viability. The transduction process can also be repeated if desired. For a lentivector with a fluorescent reporter (such as GFP), FACS can be used to enrich for cells that express GFP. If it contains a drug selectable marker, follow the protocol for the particular drug. For example, puromycin selection is usually carried out at 1-10 μg/mL, depending on the target cells’ sensitivity
Important Safety Information
With the safety features in place, our lentiviral vectors and viral particles can be employed in standard Biosafety Level 2 tissue culture facilities and should be treated with the same level of caution as any other potentially infectious agent. Any investigator who purchases our lentiviral/retroviral products & services is responsible for following Biosafety Level 2 requirements on the handling of viral particles. For more information on Biosafety Level 2 agents and practices, please refer to NIH’s “Biosafety Considerations for Research with Lentiviral Vectors”.
FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE IN HUMAN.
1. Cell 60:941-951(1990)
2. Nat. Genet. 20:394-397(1998)
3. Structure 17:54-65(2009)
4. Blood 96:2803-2807(2000)
5. Nat. Genet. 39:1083-1091(2007)
Additional supporting documents, including Product data sheet (PDS), COA and MSDS are available upon request.
FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE IN HUMAN.
Restriction: This product is not transferable or re-sellable. Customer obtain no right to transfer, assign, or sublicense its use rights, or to transfer, resell, package, or otherwise distribute the product, or to use the product for the benefit of any third party or for any commercial purpose. Customer may only use the product in compliance with applicable local, state and federal laws, regulations and rules. Customer may not directly or indirectly use the product or allow the transfer, transmission, export or re-export of all or any part of the product in violation of any export control law or regulation of the united states or any other relevant jurisdiction. Your use of this product constitutes acceptance of the terms of this limited use agreement. Please refer to our “terms & conditions” for details. If you are not willing to accept the limitation of this agreement, G&P Biosciences will accept return of the product for a full/partial refund.