Mouse Lin28 Lentivirus, Full-length Gene in Lentivector, EF1a Promoter, Pre-packaged Lentiviral Particles
RNA-binding protein Lin-28 is also known as Lin-28A (protein lin-28 homolog A (C. elegans)), ZCCHC1 (Zinc finger CCHC domain-containing protein 1) and CSDD1. Lin-28 belongs to the Lin-28 family and contains 2 CCHC-type zinc finger and 1 CSD (cold-shock) domains. Lin-28 functions as a translational enhancer that drives specific mRNAs to polysomes and increases the efficiency of protein synthesis. This results in an increased number of initiation events per molecule of mRNA and, indirectly, in mRNA stabilization. Lin28 is expressed in embryonic stem cells, fetal liver, placenta and testis and up-regulated in certain tumors. Its expression decreases during differentiation of ES cells or upon induction of neuronal differentiation by retinoic acid. Lin-28 binds IGF2 mRNA, MYOD1 mRNA, ARBP ribosomal protein mRNA and its own mRNA. It is essential for skeletal muscle differentiation through the translational up-regulation of IGF2 expression. Lin-28 is a suppressor of microRNA (miRNA) biogenesis, including that of let-7, miR107, miR-143 and miR-200c. It specifically binds miRNA precursors (pre-miRNAs), recognizes a 5'-GGAG-3' motif found in pre-miRNA terminal loop, and recruits ZCCHC11/TUT4 uridylyltransferase, leading to the terminal uridylation of target pre-miRNAs. Uridylated pre-miRNAs fail to be processed by Dicer and undergo degradation. This may help maintain the pluripotent state by preventing let-7-mediated differentiation of embryonic stem cells. The CSD domain is required for function in muscle differentiation while the CCHC zinc fingers interact with the GGAG motif at the 3' end of let-7 miRNAs precursors.
Gene Symbol: Lin28; CSDD1; LIN-28; ZCCHC1; Lin-28A Tex17; Gm10299; AL024421 ENSMUSG00000070700
NCBI Gene ID: 83557
Uniprot Entry: Q8K3Y3
Construct Details: Full length mouse Lin28 gene is subcloned into the Lentiviral expression vector pLTE with an upstream EF1α promoter and with or without a selection marker, which can be used for both transient and stable expression in mammalian cells. It can be co-transfected with the LentiPAK DNA mix (SKU# LP-001) into HEK293 cells to produce high titer lentiviral particles. Multiple selection markers are available.
Vector Type: pLTE or pLTE-IRES-Marker (lentiviral expression vector containing a heterologous EF1α promoter, see the vector map above)
Gene Insert Size: 630 (bp)
Gene Insert Sequence:
ATGGGCTCGGTGTCCAACCAGCAGTTTGCAGGTGGCTGCGCCAAGGCAGCGGAGAAGGCGCCAGAGGAGGCGCCGCCTGA
CGCGGCCCGAGCGGCAGACGAGCCGCAGCTGCTGCACGGGGCCGGCATCTGTAAGTGGTTCAACGTGCGCATGGGGTTCG
GCTTCCTGTCTATGACCGCCCGCGCTGGGGTCGCGCTCGACCCCCCGGTGGACGTCTTTGTGCACCAGAGCAAGCTGCAC
ATGGAAGGGTTCCGAAGCCTCAAGGAGGGTGAGGCGGTGGAGTTCACCTTTAAGAAGTCTGCCAAGGGTCTGGAATCCAT
CCGTGTCACTGGCCCTGGTGGTGTGTTCTGTATTGGGAGTGAGCGGCGGCCAAAAGGGAAGAACATGCAGAAGCGAAGAT
CCAAAGGAGACAGGTGCTACAACTGCGGTGGGCTAGACCATCATGCCAAGGAATGCAAGCTGCCACCCCAGCCCAAGAAG
TGCCACTTTTGCCAAAGCATCAACCATATGGTGGCCTCGTGTCCACTGAAGGCCCAGCAGGGCCCCAGTTCTCAGGGAAA
GCCTGCCTACTTCCGGGAGGAAGAGGAAGAGATCCACAGCCCTGCCCTGCTCCCAGAAGCCCAGAATTGA
Formulation: Pre-packaged lentiviral particles in the conditional medium (serum-free) from HEK293 cells (typical titer 106 - 107 IFU/ml)
FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE IN HUMAN.
Important Safety Information: With the safety features in place, our lentiviral vectors and viral particles can be employed in standard Biosafety Level 2 tissue culture facilities and should be treated with the same level of caution as any other potentially infectious agent. Any investigator who purchases our lentiviral/retroviral products & services is responsible for following Biosafety Level 2 requirements on the handling of viral particles. For more information on Biosafety Level 2 agents and practices, please refer to NIH’s “Biosafety Considerations for Research with Lentiviral Vectors”.
Restriction: This product is not transferable or re-sellable. Customer obtain no right to transfer, assign, or sublicense its use rights, or to transfer, resell, package, or otherwise distribute the product, or to use the product for the benefit of any third party or for any commercial purpose. Customer may only use the product in compliance with applicable local, state and federal laws, regulations and rules. Customer may not directly or indirectly use the product or allow the transfer, transmission, export or re-export of all or any part of the product in violation of any export control law or regulation of the united states or any other relevant jurisdiction. Your use of this product constitutes acceptance of the terms of this limited use agreement. Please refer to our “terms & conditions” for details. If you are not willing to accept the limitation of this agreement, G&P Biosciences will accept return of the product for a full/partial refund.
Pre-packaged lentiviral particles are most advanced gene delivery tools. Each particles contain a fully sequence verified target gene and are psudotyped with the VSV-G glycoprotein, ready for transduction into a wide range of cell types including hard-to-transfect primary cells and non-dividing cells. They are supplied in 1-mL aliquot(s) of the serum-/antibiotic-free solution suitable for both in vitro and in vivo delivery. They are produced in HEK293 packaging cells with a typical titer of ≥107 IFU/ml using our optimized LentPAKTM packaging system. The lentiviral particles can be used to transduce subconfluent target cells. Depending on your purpose, you may choose a specific multiplicity of infection (MOI) or test a range of MOIs to determine which gives you the desired results. Transduction can be enhanced by the addition of polybrene, also known as hexadimethrine bromide (typically at 8-10 μg/ml).
Quick Protocol for Transduction
Day 1. Seeding Target Cells
For an example, plate target cells in a 10 cm plate at a density of 1 - 5x 105 cells/ml that will produce approximately 60% confluency in 24 hours.
Note: other size plates can also be used depending on the nature of your experiment. Adjust the reagent amount according to Table 1
Table 1. Seeding Density of Target Cells (1 day prior to transduction)
Vessel Type |
Seeding Target Cell# |
Volume of Media |
10-cm dish |
1 – 5 x 106 |
10 mL |
6-well plate |
0.3 – 1 x 106 |
2 mL/well |
12-well plate |
0.15 – 0.5 x 106 |
1 mL/well |
24-well plate |
0.6 – 2 x 105 |
0.5 mL/well |
96-well plate |
1 – 4 x 104 |
0.1 mL/well |
Day 2. Transduction
Remove the growth media from the dish/plate prepared the day before. Replace with 1/2 volume of culture medium containing desired amount of lentiviral particles (at 2 to 20 MOI). For example, add 4.5 mL of growth medium and 0.5 mL of Lentiviral particles, or simply add 5 mL of Lentiviral particles (for a low titer viral preparation or a high MOI transduction). Add polybrene directly to the media on the target cells at 8 μg/ml. Mix by gentle swirling.
Incubate at 37°C with 5% CO2 for 4 - 24 hours, then replace the transduction medium with right amount of growth medium according to table 1 (for example 10 mL for 10-cm dish). Culture the cells for 48 – 72 hours, and transduced cells are ready for downstream analyses.
Note: Adjust volumes accordingly for transduction of other plate types. For example, add 1 ml of growth medium and lentiviral particle mixture for 6-well plate, 0.5 ml for 12-well and 0.25 mL for 24-well except for 96 well, in which 100 μl should be used. The change of transduction medium is often unnecessary with our pre-packaged lentiviral particles. Simply culture cells for 3-4 days before analysis.
The virus-containing media can be changed in as short as 4 hours after transduction if toxicity of the lentiviral transduction is a concern. Normally reverse transcription and genome integration of the lentivector takes place within 24-36 hours. With our ready-to-use, prepackaged lentiviral particles, the change of media is often unnecessary. The transduction process can be ongoing for 2 - 6 days without significant impact on cell growth/viability. The transduction process can also be repeated if desired. For a lentivector with a fluorescent reporter (such as GFP), FACS can be used to enrich for cells that express GFP. If it contains a drug selectable marker, follow the protocol for the particular drug. For example, puromycin selection is usually carried out at 1-10 μg/mL, depending on the target cells’ sensitivity
Important Safety Information
With the safety features in place, our lentiviral vectors and viral particles can be employed in standard Biosafety Level 2 tissue culture facilities and should be treated with the same level of caution as any other potentially infectious agent. Any investigator who purchases our lentiviral/retroviral products & services is responsible for following Biosafety Level 2 requirements on the handling of viral particles. For more information on Biosafety Level 2 agents and practices, please refer to NIH’s “Biosafety Considerations for Research with Lentiviral Vectors”.
Poor Transduction Efficiency:
Poor transduction efficiency could be due to a low viral titer. While lentivectors can accommodate relatively large inserts (up to 8 kb) comparing to other systems, there is still a packaging limit. In general, lentivectors could transfer up to 8-kb gene inserts. However, any gene insert larger than 4kb will dramatically decreases packaging efficiency, which would results in a lower viral titer. To overcome low titers, concentrate viral particles or lower target cell density for transduction. If the transduction efficiency is low despite a high titer of virus, the total volume of transduction media on the target cells may be too high. Transduction can be carried out in a volume of media that just covers the cells; this may increase the exposure of the cells to the virus. Low speed spin (e.g., 1500 rpm for 15-30 min) may help increase the likelihood of virus-cell interactions. Pseudotyping of the transducing virus to target more abundant receptors on a particular cell type is another potential approach.
Transduction Kills Target Cells:
It is possible that MOI may be too high. Perform the transduction with a lower MOI or less viral particles. Packaging cell medium may not be compatible for target cell growth. Either dilute the virus in target cell-compatible medium or concentrate and resuspend the virus in medium compatible with the target cell growth. Change the transduction media containing the virus as early as 4 hrs after transduction.
FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE IN HUMAN.
The product is shipped at 4°C for immediate use or frozen with dry ice. Upon receipt, centrifuge the vial briefly before opening. Store at –80°C or lower and the product is stable for 3 months. Avoid repeated freeze-thaw cycles.
The product should be employed in a Biosafety Level 2 tissue culture facility.
FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE IN HUMAN.
1. Stem Cells 22:51 (2004)
2. J. Biol. Chem. 280:16635 (2005)
3. Mol. Cell 32:276 (2008)
4. Cell 138:696 (2009)
5. Nat. Genet. 41:843 (2009)
6. Cell 147:1066 (2011)
Product datasheet (pdf) can be downloaded here: LEV0029-PDS.pdf
Additional supporting documents, including COA and MSDS are available upon request.
FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE IN HUMAN.
Restriction: This product is not transferable or re-sellable. Customer obtain no right to transfer, assign, or sublicense its use rights, or to transfer, resell, package, or otherwise distribute the product, or to use the product for the benefit of any third party or for any commercial purpose. Customer may only use the product in compliance with applicable local, state and federal laws, regulations and rules. Customer may not directly or indirectly use the product or allow the transfer, transmission, export or re-export of all or any part of the product in violation of any export control law or regulation of the united states or any other relevant jurisdiction. Your use of this product constitutes acceptance of the terms of this limited use agreement. Please refer to our “terms & conditions” for details. If you are not willing to accept the limitation of this agreement, G&P Biosciences will accept return of the product for a full/partial refund.