Human GPR50 Gene, Full-length cDNA Clone in Lentivector, Endotoxin-free DNA
GPR50 (G-protein coupled receptor 50) is a 7 transmembrane receptor belonging to the G protein-coupled receptor 1 (GPCR1) family. GPR50 shares similarity with the melatonin receptors. However it does not bind melatonin and inhibits melatonin receptor 1A function through heterodimerization. Polymorphic variants of the GPR50 gene have been associated with bipolar affective disorder in women.
Gene Symbol: GPR50; H9; Mel1c
NCBI Gene ID: 9248
Uniprot Entry: Q13585
Construct Details: Full length human GPR50 gene is subcloned into the Lentiviral expression vector pLTC with an upstream CMV promoter and with or without a selection marker, which can be used for both transient and stable expression in mammalian cells. It can be co-transfected with the LentiPAK DNA mix (SKU# LP-001) into HEK293 cells to produce high titer lentiviral particles. Multiple choices of a stable antibiotic selection marker are available.
Vector Type: pLTC or pLTC-IRES-Marker (lentiviral expression vector containing a heterologous CMV promoter, see the vector map above)
Formulation: Supplied with 10 μg of endotoxin-free plasmid DNA at 200 ng/μl in sterile TE buffer (pH8.0)
Gene Insert Size: 1854 (bp)
Gene Insert Sequence:
ATGGGGCCCACCCTAGCGGTTCCCACCCCCTATGGCTGTATTGGCTGTAAGCTACCCCAGCCAGAATACC
CACCGGCTCTAATCATCTTTATGTTCTGCGCGATGGTTATCACCATCGTTGTAGACCTAATCGGCAACTC
CATGGTCATTTTGGCTGTGACGAAGAACAAGAAGCTCCGGAATTCTGGCAACATCTTCGTGGTCAGTCTC
TCTGTGGCCGATATGCTGGTGGCCATCTACCCATACCCTTTGATGCTGCATGCCATGTCCATTGGGGGCT
GGGATCTGAGCCAGTTACAGTGCCAGATGGTCGGGTTCATCACAGGGCTGAGTGTGGTCGGCTCCATCTT
CAACATCGTGGCAATCGCTATCAACCGTTACTGCTACATCTGCCACAGCCTCCAGTACGAACGGATCTTC
AGTGTGCGCAATACCTGCATCTACCTGGTCATCACCTGGATCATGACCGTCCTGGCTGTCCTGCCCAACA
TGTACATTGGCACCATCGAGTACGATCCTCGCACCTACACCTGCATCTTCAACTATCTGAACAACCCTGT
CTTCACTGTTACCATCGTCTGCATCCACTTCGTCCTCCCTCTCCTCATCGTGGGTTTCTGCTACGTGAGG
ATCTGGACCAAAGTGCTGGCGGCCCGTGACCCTGCAGGGCAGAATCCTGACAACCAACTTGCTGAGGTTC
GCAATTTTCTAACCATGTTTGTGATCTTCCTCCTCTTTGCAGTGTGCTGGTGCCCTATCAACGTGCTCAC
TGTCTTGGTGGCTGTCAGTCCGAAGGAGATGGCAGGCAAGATCCCCAACTGGCTTTATCTTGCAGCCTAC
TTCATAGCCTACTTCAACAGCTGCCTCAACGCTGTGATCTACGGGCTCCTCAATGAGAATTTCCGAAGAG
AATACTGGACCATCTTCCATGCTATGCGGCACCCTATCATATTCTTCTCTGGCCTCATCAGTGATATTCG
TGAGATGCAGGAGGCCCGTACCCTGGCCCGCGCCCGTGCCCATGCTCGCGACCAAGCTCGTGAACAAGAC
CGTGCCCATGCCTGTCCTGCTGTGGAGGAAACCCCGATGAATGTCCGGAATGTTCCATTACCTGGTGATG
CTGCAGCTGGCCACCCCGACCGTGCCTCTGGCCACCCTAAGCCCCATTCCAGATCCTCCTCTGCCTATCG
CAAATCTGCCTCTACCCACCACAAGTCTGTCTTTAGCCACTCCAAGGCTGCCTCTGGTCACCTCAAGCCT
GTCTCTGGCCACTCCAAGCCTGCCTCTGGTCACCCCAAGTCTGCCACTGTCTACCCTAAGCCTGCCTCTG
TCCATTTCAAGGCTGACTCTGTCCATTTCAAGGGTGACTCTGTCCATTTCAAGCCTGACTCTGTTCATTT
CAAGCCTGCTTCCAGCAACCCCAAGCCCATCACTGGCCACCATGTCTCTGCTGGCAGCCACTCCAAGTCT
GCCTTCAGTGCTGCCACCAGCCACCCTAAACCCACCACTGGCCACATCAAGCCAGCTACCAGCCATGCTG
AGCCCACCACTGCTGACTATCCCAAGCCTGCCACTACCAGCCACCCTAAGCCCACTGCTGCTGACAACCC
TGAGCTCTCTGCCTCCCATTGCCCCGAGATCCCTGCCATTGCCCACCCTGTGTCTGACGACAGTGACCTC
CCTGAGTCGGCCTCTAGCCCTGCCGCTGGGCCCACCAAGCCTGCTGCCAGCCAGCTGGAGTCTGACACCA
TCGCTGACCTTCCTGACCCTACTGTAGTCACTACCAGTACCAATGATTACCATGATGTCGTGGTTATTGA
TGTTGAAGATGATCCTGATGAAATGGCTGTGTGA
Primers: Gene insert coding sequence can be confirmed by following primers:
(a) forward (or 5'-end) primer: 5’-CAAATGGGCGGTAGGCGTG-3’;
(b) reverse (or 3'-end) primer: 5’-CCAGGTTTCCGGGCCCTCAC-3’
Note: The sequence may vary due to the naturally occurring variants or mutations, such as single nucleotide polymorphism, or the artifact during PCR amplification. High fidelity PCR systems should always be used.
FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE IN HUMAN.
Restriction: This product is not transferable or re-sellable. Customer obtain no right to transfer, assign, or sublicense its use rights, or to transfer, resell, package, or otherwise distribute the product, or to use the product for the benefit of any third party or for any commercial purpose. Customer may only use the product in compliance with applicable local, state and federal laws, regulations and rules. Customer may not directly or indirectly use the product or allow the transfer, transmission, export or re-export of all or any part of the product in violation of any export control law or regulation of the united states or any other relevant jurisdiction. Your use of this product constitutes acceptance of the terms of this limited use agreement. Please refer to our “terms & conditions” for details. If you are not willing to accept the limitation of this agreement, G&P Biosciences will accept return of the product for a full/partial refund.
The product is shipped at 4°C. Upon receipt, centrifuge the product briefly before opening the vial. It is recommended to store small aliquots at the temperature below –20°C for long-term storage and the product is stable for 6 months.
Use a manual defrost freezer and avoid repeated freeze-thaw cycles.
FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE IN HUMAN.
Restriction: This product is not transferable or re-sellable. Customer obtain no right to transfer, assign, or sublicense its use rights, or to transfer, resell, package, or otherwise distribute the product, or to use the product for the benefit of any third party or for any commercial purpose. Customer may only use the product in compliance with applicable local, state and federal laws, regulations and rules. Customer may not directly or indirectly use the product or allow the transfer, transmission, export or re-export of all or any part of the product in violation of any export control law or regulation of the united states or any other relevant jurisdiction. Your use of this product constitutes acceptance of the terms of this limited use agreement. Please refer to our “terms & conditions” for details. If you are not willing to accept the limitation of this agreement, G&P Biosciences will accept return of the product for a full/partial refund.
Additional supporting documents, including product datasheet, COA and MSDS are available upon request.
FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE IN HUMAN.
Restriction: This product is not transferable or re-sellable. Customer obtain no right to transfer, assign, or sublicense its use rights, or to transfer, resell, package, or otherwise distribute the product, or to use the product for the benefit of any third party or for any commercial purpose. Customer may only use the product in compliance with applicable local, state and federal laws, regulations and rules. Customer may not directly or indirectly use the product or allow the transfer, transmission, export or re-export of all or any part of the product in violation of any export control law or regulation of the united states or any other relevant jurisdiction. Your use of this product constitutes acceptance of the terms of this limited use agreement. Please refer to our “terms & conditions” for details. If you are not willing to accept the limitation of this agreement, G&P Biosciences will accept return of the product for a full/partial refund.