Human VSIG10L2 Gene, Full-length cDNA Clone in Lentivector, Endotoxin-free DNA
VSIG10L2 (V-set and immunoglobulin domain-containing protein 10-like 2) is a single pass type I transmembrane protein belonging to the Immunoglobulin superfamily (IgSF). VSIG10L contains a 749 aa extracellular region (ECD) with 5 Ig-like (Ig) domains and 1 fibronectin type-III domain, a transmembrane (TM) domain and a cytoplasmic tail. VSIG10L2 contains multiple glycosylation sites at the N-terminal ECD region. The function of VSIG10L2 is unclear.
Gene Symbol: VSIG10L2
Uniprot Entry: P0DP72
Construct Details: Full length human VSIG10L2 gene is subcloned into the Lentiviral expression vector pLTC with an upstream CMV promoter and with or without a selection marker, which can be used for both transient and stable expression in mammalian cells. It can be co-transfected with the LentiPAK DNA mix (SKU# LP-001) into HEK293 cells to produce high titer lentiviral particles. Multiple choices of a stable antibiotic selection marker are available.
Vector Type: pLTC or pLTC-IRES-Marker (lentiviral expression vector containing a heterologous CMV promoter, see the vector map above)
Formulation: Supplied with 10 μg of endotoxin-free plasmid DNA at 200 ng/μl in sterile TE buffer (pH8.0)
Gene Insert Size: 2304 (bp)
Gene Insert Sequence:
ATGGTGGGTCAGAGGGCCCAGCACAGCCCAGTCAGCCTCCTGCTGCTGATACACCTCTGCCTTCTGCACCTGAGGGCCTC
AGGCCAGCCCCACCCGACCCCCGAGGCCCCTGTAGAGGAGGTGGTGTCTGTCCAGGGAGTGCGAGGTGGCTCCGTGGAGC
TGGCCTGTGGCTCAGGGCCTGCCCCGCTGCTGGTCCTCTGGAGCTTCACCCCCCTGGGCTCCCTGGTTCCCCGGCCTGTG
GCCGTCACCGATGGAGCCATGTCCAAGGTGGAGGCCATCGCCTCGGCTCTGGGAGTCGTGAGTCTGAGGAACAGCAGCCT
GGTGCTGGGGGAGCTTCACGAGGGTGCCCGTGGCCACTTCCTATGCCAGGTTCTGCACGTGGCTGGCGGCCAGCTCCACG
CTGCCTACTCCCACCTCACGCTGGCTGTGCTGGTGCCGGTGTCCAAGCCTCAAGTGCGACTGAGTAACCCGTCCCCTGTG
GAGGGAGCCTCCGTGGTGGCCACGTGTGCAGTGCGGGAGGGCACAGAGCCCGTGACCTTTGCCTGGCAGCATCGGGCACC
CCGAGGCCTTGGAGAGGCCCTGGTGGGGGTCACTGAGCCACTATTCCAGCTGGACCCTGTCAACCGGACACACCTAGGGT
GGTACATGTGCAGCGCCAGCAACTCCGTGAACAGGCTGAGCAGTGACGGGGCCTTCCTGGACGTCATTTATGGTCCTGAC
AAGCCTGTGATCACCATGGAGCCGCTGGGACTCACTGAGGAGGGCTTCTGGGCCAGTGAGAGGGAAGAGGTGACCCTGAG
CTGTCTGGCTGCCTCCAACCCACCTAGTCACTATGTGTGGCTCCGTGACCACACGCAAGTCCACACGGGGCCTACCTATG
TCATCGCCAGAGCTGGCCGTGTCCACACAGGCCTGTACACCTGCCTGGCCCGCAACAGCTACCTGGACACCCGCACCCAG
ACTACTGTCCAGCTCACCATCTACTATCCCCCTGAGGGACAGCCCTCCTGTGCAGTGCATCCCAGCCCTGAGGCTGTGAC
CCTGCTCTGTGCCTGGCCTGGGGGGCTTCCGCCTGCCCAACTGCAGTGGGAAGGGCCTCAGGGACCTGGCCCTACTGCCC
CCAGCAACGTCACCTGGAGTCACGCAGCCGCCCAGCTCCCCAGTGGCAGCGTCTTCACCTGCACTGGCCAGCACCCAGCC
CTGGCACCGCCTGCCCTCTGCACAGTCATGCTCTGGGAGCCTCTCGGGAGGCCTACCTGCTGGAGCACAGCCACAATGGG
GGACCAGTTCATCATGCTGAGCTGCGAGTGGCCTGGCGGCGAGCCCCCTGCCACGCTGGGCTGGCTTGACGAACAGCAGC
AGCCCCTGGGCGGCAGCAGCTCCTCGATGGCCGTTCACCTCCTGCAGGCCCAAGAAGATCTGGCTGGCAGAGAGTTCACC
TGCCGGGGCACTCACCTGCTCAGGACCCCTGACCCCCACTGCCACCTCCAGCTGGAAGCCCCACAGCTGGACGTGGCTGA
GCCCCGCGTGTCAGTGTTGGAGGGGGGAGAGGCCTGGCTGGAGTGCTCTCTCCGCGGGGGCACACCACCTGCCCAGCTCC
TCTGGCTGGGGCCTCAACAACAAAAAGTGGACCCCGGCACTTCAGGATTCATGCTGCACCCTGAGGGTGCCCAGCTGCGC
CTGGGCATCTACGATGCTGACCCGGCACACCACAGGGGCACCTACCAATGCGTGGCCCGCAACGCCGTGGGCAATAGCAG
TCAGAGTGTGCTGCTGGAGGTCCTGAGATATCCAGCTCCTCCCAATGTCACCATCAGCCGCCTGACCTACGGGAGGCACC
GGAGAGAGGTGCAGCTTCAATGGGCCATCTTAGGACCCGGGAACCTGACGGGCTTCCTGGTGCAGCGGAAGGCCAGTGCC
CTGGGCCCAGGAGCTGGGGCGTGGGAGACAGCAGCTAGTGACATCGAGCCAGAGAGCCGAGGACGGCGGCTGGGGGGCTT
GGACCCCGGGGTCCTTTATGCCTTCCGCATCCTGGCTCTGAATCACCACACTGCAGGACATCCCTCTGAGGTGAAGATAC
CAGCGGACCCCCCCTTCAGCGCCTACCCAGCGGTGTTGGGTGCAGCAGGCACGGGAATGGTGGTAGCAACGGTGGCCTCT
CTACTGGTGTTCCAGTATGCTGCCCGGCACCCAGAGACTTTCCCCCGCCTTGAAACACCAACCACCACCCCAGGTTTGGA
TCCTGCACAAGAAACCACGGATTCTCCAGTGAATGTCACCATCACAGTGACTGCAACACCATAA
Primers: Gene insert coding sequence can be confirmed by following primers:
(a) forward (or 5'-end) primer: 5’-CAAATGGGCGGTAGGCGTG-3’;
(b) reverse (or 3'-end) primer: 5’-CCAGGTTTCCGGGCCCTCAC-3’
Note: The sequence may vary due to the naturally occurring variants or mutations, such as single nucleotide polymorphism, or the artifact during PCR amplification. High fidelity PCR systems should always be used.
FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE IN HUMAN.
Restriction: This product is not transferable or re-sellable. Customer obtain no right to transfer, assign, or sublicense its use rights, or to transfer, resell, package, or otherwise distribute the product, or to use the product for the benefit of any third party or for any commercial purpose. Customer may only use the product in compliance with applicable local, state and federal laws, regulations and rules. Customer may not directly or indirectly use the product or allow the transfer, transmission, export or re-export of all or any part of the product in violation of any export control law or regulation of the united states or any other relevant jurisdiction. Your use of this product constitutes acceptance of the terms of this limited use agreement. Please refer to our “terms & conditions” for details. If you are not willing to accept the limitation of this agreement, G&P Biosciences will accept return of the product for a full/partial refund.
The product is shipped at 4°C. Upon receipt, centrifuge the product briefly before opening the vial. It is recommended to store small aliquots at the temperature below –20°C for long-term storage and the product is stable for 6 months.
Use a manual defrost freezer and avoid repeated freeze-thaw cycles.
FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE IN HUMAN.
Additional supporting documents, including PDS, COA and MSDS are available upon request.
FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC USE IN HUMAN.
Restriction: This product is not transferable or re-sellable. Customer obtain no right to transfer, assign, or sublicense its use rights, or to transfer, resell, package, or otherwise distribute the product, or to use the product for the benefit of any third party or for any commercial purpose. Customer may only use the product in compliance with applicable local, state and federal laws, regulations and rules. Customer may not directly or indirectly use the product or allow the transfer, transmission, export or re-export of all or any part of the product in violation of any export control law or regulation of the united states or any other relevant jurisdiction. Your use of this product constitutes acceptance of the terms of this limited use agreement. Please refer to our “terms & conditions” for details. If you are not willing to accept the limitation of this agreement, G&P Biosciences will accept return of the product for a full/partial refund.